HOME > 제품소개 > 교정용 표준기
5730A Multi-function Calibrator
 
이전 버전과 마찬가지로 5730A는 최대 롱 스케일 8.5 디지트 DMM 및 RF 전압계(광대역 옵션이 포함된 경우) 등 다양한 디지털 멀티미터를 교정할 수 있습니다. 이와 더불어 이 새로운 모델에는 테스트 불확도 비(TUR)와 테스트 신뢰도를 높일 수 있는 향상된 사양이 포함되어 있습니다. 또한 향상된 사양으로 인해 가드밴드를 사용할 필요가 없으므로 자신 있게 안심하고 교정할 수 있습니다.
관련 문의 : 054)451-8655
E-mail 문의 : sales@inssol.co.kr
  • Improved performance specifications for ac voltage, ac current and resistance
  • 6.5 inch VGA capacitive touch screen with full color graphical user interface
  • Visual Connection Management™ output terminals guide connections
  • Graphical user interface in nine languages
  • Compatible with 52120A and 5725A amplifiers
  • Full MET/CAL® compatibility with 5700A and 5720A procedures
  • Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards

 

Technical Specifications
Voltage DC
Range:  0 to ±1100 V
Best 1 Year, 95% Specification:  3.5 ppm + 2.5 µV
Voltage AC
Ranges:  220 mV to 1100V
   10 Hz to 1 MHz
Best 1 Year, 95% Specification: 42 ppm + 8 µV
Resistance
Ranges:  0 to 100 MΩ, 18 values in x1 and x1.9
Best 1 Year, 95% Specification:  6.5 ppm
Current DC
Ranges:  0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A)
Best 1 Year, 95% Specification:  35 ppm + 7 nA
Current AC
Ranges:  9 µA to 2.2A, 10 Hz to 10 kHz (9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A)
Best 1 Year, 95% Specification  103 ppm + 8 nA
Wideband ac Voltage option
Ranges:  300 µV to 3.5V
   10 Hz to 30 MHz
Best 1 Year, 95% Specification  ±0.4% of setting

 

General Specifications
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes
Settling time Less than 5 seconds for all functions and ranges except as noted
Standard interfaces IEEE-488 (GPIB), RS-232, USB 2.0 Device, Ethernet, 5725A, 52120A, phase lock in (BNC), phase reference out (BNC)
Temperature performance
Operating:  0 °C to 50 °C
Calibration:  15 °C to 35 °C
Storage:  -40 °C to 75 °C
 Operating altitude  2000 m maximum
Relative humidity
Operating:  < 80% to 30 °C, < 70% to 40 °C, < 40% to 50 °C
Storage:  < 95%, non-condensing.
Safety IEC 61010-1: 300 V CAT II, Pollution Degree 2
Analog low isolation 20 V
Electromagnetic environment IEC 61326-1: Controlled
Line power 47 Hz to 63 Hz; ±10% 100 V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V
Power consumption 300 VA
Dimensions
Height::  17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet
Width::  43.2 cm (17 in), standard rack width
 Depth:  64.8 cm (25.5 in), overall; 59.4 cm (23.4 in), rack depth
Weight
27 kg: (62 lbs.)
Absolute uncertainty definition 5730A uncertainty specifications include stability, temperature coefficient, linearity, load regulation, and the traceability of th eexternal standars used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated
Specification confidence interval 99% and 95%
Model Name Description
5730A

Multifunction Calibrator 

5730A/03

Multifunction Calibrator with Wideband AC Voltage Option 

5730A/S

Multifunction Calibrator with No Front Panel USB Port 

52120A

Transconductance Amplifier

5725A

Amplifier 

MET/CAL-L

License for MET/CAL, includes capabilities of MET/TRACK. MET/BASE-8 or earlier version required.

Accessories common to all models:

Accessory Description
5730A-7002

Low Thermal EMF Cables with Banana Plugs 

5730A-7003

Low Thermal EMF Cables with Space Connectors 

Y5737

5790A and 5700A/5720A Rack Mount Kit. Includes 24 in. slides that allow for side ventilation

Y5738

5730A Rack Ear Kit 

57XX/CASE

Transit Case for 57XXA Series